Table 1

Intention to diagnose per-patient performance of second-generation capsule colonoscopy in the detection of polyps

Polyp size (mm)Polyp prevalence n (%)CC2 per segment matching analysis
(N=50 patients)Sensitivity
% (95% CI)
Specificity
% (95% CI)
≥615 (30%)93.3 (66.0 to 99.7)80.0 (62.5 to 90.9)
≥107 (14%)100.0 (56.1 to 100.0)93.0 (79.9 to 98.2)
  • CC2, second-generation capsule colonoscopy.